Pull straighten and push technique: A simple solution for guidewire realignment to facilitate stent and device delivery in coronary angioplasty

Authors

  • Byju Kachery
  • Biju Ephrem
  • Sreeram Gopalakrishnan

DOI:

https://doi.org/10.32677/IJCR.2017.v03.i04.017

Keywords:

Balloon angioplasty, Coronary artery disease, Percutaneous coronary intervention, Pull straighten and push technique, Stenting technique

Abstract

Coronary guidewire bias prevents easy passage of interventional devices such as stents and balloons during percutaneous coronary intervention (PCI). Realigning guidewire into the central part of the lumen, away from the coronary wall helps the tracking devices
in situations with significant guidewire bias. There are several available techniques to facilitate stent delivery in tortuous vessel; however, these techniques have their own limitations and can be expensive and time-consuming. A new maneuver for easy passage
of stents and balloons in these situations by guidewire realignment is described in this report. This maneuver namely “pull straighten and push technique” demonstrated an easy procedure to successfully execute stents or devices deployment in challenging PCIs.

Downloads

Download data is not yet available.

Downloads

Published

2020-11-06

How to Cite

Pull straighten and push technique: A simple solution for guidewire realignment to facilitate stent and device delivery in coronary angioplasty. (2020). Indian Journal of Case Reports, 3(4), 220-223. https://doi.org/10.32677/IJCR.2017.v03.i04.017

Most read articles by the same author(s)

<< < 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 > >>